C100 Series Basic Driver Card
C100 Series Driver Card
Our C100 series driver card allows for manual settings that control the speed, direction, motor wattage, reset and high-performance mode functions for the InfiniDrive™ MDR powered roller. We also include the ability to use the on-board speed control or external speed control. Easy I/O connection points for your start, stop, direction, or PLC inputs as well as fault outputs. Plug-and-play system using JST-10 connectors on both the driver card and InfiniDrive™ MDR powered roller. Connecting to a PLC makes monitoring, controlling and optimizing performance easier than ever.
-
On-board acceleration/deceleration pot—for ramp up and ramp down timing based on product load
-
Discrete speed selection for accurate zone-to-zone control
-
Internal thermistors—to monitor operating heat and provide additional safety
-
Multiple fault indications for more thorough troubleshooting
-
8 Position DIP switch bank
-
22 Watt and 35 Watt motor selectable
-
Direction of rotation
-
Reset mode—auto or manual
-
See catalog for additional settings
-
-
Dynamic Braking
-
Model C100B has a torque boost mode
-
Model C100EB provides electronic brake and hold
-
Model C100MB includes a mechanical brake
-
CE Certified
Specifications

Part numbers
C100B, C100EB, and
C100MB
Driver card for 22W and 35W rollers and 35W gear motor
Electrical Power
Termination
Voltage Range
Current Consumption
Plug-In Cage Clamp Terminal
24V DC (+/-10%)
100 mA plus motorized roller
Motor Connection
Type
Number
Termination
Voltage Range
Max Average Current
EcoSmart™ powered roller or gear motor
1
JST XHP-10 Pin connecter
24V DC
2.5/3.0 Amps (22W/35W)
Control Port
Type
Number
Termination
Voltage Range
Maximum Current
Current Sinking Inputs/Outputs
1
Plug-In cage clamp terminal
24V DC
2.5/3.0 Amps (22W/35W)
Speed Control
Internal Potentiometer
External PLC
1000-3400 rpm (22W)
1000-4000 rpm (35W)
25 - 100% of roller speed rating
Environmental
Storage Temp.
Operating Temp.
Humidity
Vibration
Shock
-30° to 70° C (-22° to 158° F)
0° to 60° C (32° to 140° F)
5-95% RH, non-condensing
2G at 10 to 500 Hz
10G
Physical
Size
Mounting
Status Indication
See drawing below.
See mounting dimensions below.
See catalog.

Dimensions
Dimensions in mm

Mounting Dimensions: 4.5mm max holes at 40mm x 120mm pattern




Configuration
DIP Switch Bank
DIP Switches are used to configure the functionality of the C100 series driver card. The switches are numbered 1-8, beginning with the switch furthest to the left. DIP Switches 1-4 are used to set correct operation, with 5-8 reserved for speed settings.
DIP Switch 1 allows the driver card to be used with either
a 22W or 35W InfiniDrive™ MDR powered roller. DIP Switch 2 is reserved. See catalog for standard DIP 2 functionality based on part number. DIP Switch 3 sets the direction of rotation. DIP Switch 4 determines how application Faults are reset: OFF requires a power cycle to clear the faults, ON allows the driver to reset automatically after 10 seconds.
Internal Potentiometer, Acceleration and Deceleration Settings
The C100 series driver card has an internal potentiometer located to the right of the DIP Switch bank. DIP Switches 5-8 must be set to ON for the internal potentiometer to control the speed. The C100 series driver card also includes an acceleration and deceleration potentiometer that can be used to set the ramp up and ramp down times. Acceleration and deceleration can be set between 10 and 1.6 (clockwise) RPM/milliseconds.
Speed Settings

The C100 series driver card offers three methods to set the speed. See the charts below.
RPM Chart for 22W
InfiniDrive™ MDR Powered Roller
RPM Chart for 35W
InfiniDrive™ MDR Powered Roller

FPM Speed calculation: .2618 x Diameter in Inches x Motor RPM / Gearbox Ratio
M/S Speed calculation: .00053 x Diameter in mm x RPM / Gearbox Ratio